[{"_geo": {"lat": 51.517502, "lng": -0.617843}, "amenities": ["Client Implementation Services", "Installation Services", "24/7 Remote Hands Services", "Facility Services", "Audit Support Services"], "certifications": ["ISO 9001", "ISO/IEC 27001", "ISO 22301", "ISO 50001", "ISO 45001", "ISO 14001", "PCI DSS", "ISAE 3402 Type 2 Report"], "facility": {"address": "665 Ajax Avenue", "city": "Slough", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Carrier- and cloud-neutral", "Carrier-mix", "Connectivity and dark fiber infrastructure", "Carrier-Meet-Me-Rooms", "Redundant cabling infrastructure", "Pre-Cabling to support fast Cross Connect deployments", "High-performance internet access", "Inter data center connectivity between NTT data centers", "Multi Service Interconnection Platform"]}, "country": "United Kingdom", "name": "Slough 3", "overview": "Slough 3 Data Center is designed for flexible and evolving requirements. Located in the UK\u2019s second-largest data center cluster, it offers carrier-neutral connectivity, high-performance colocation, and robust security infrastructure. The facility provides tailored infrastructure with global connectivity options.", "state": "NULL", "stateAbbr": "NULL", "url": "/ntt-slough-3", "worldRegion": "europe", "yearBuilt": "NULL", "zipcode": "SL1 4BG"}, "hasSecurity": true, "id": 182, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Primary cooling infrastructure, centrally managed and linked to BMS, room air conditioning units, regulated humidity, 1.5m clear false ceiling void for hot-air return, contained hot aisle or chimney rack design", "redundancy": "NULL"}, "density": "2.7MW IT load", "standbyPower": {"configuration": "N+1 backup generators, refueling contracts to ensure timely replacement", "redundancy": "N+1"}, "ups": {"configuration": "Minimum 2N UPS with battery backup", "redundancy": "2N"}, "utilityFeeders": "Dual dedicated 11,000V (HV) grid connections (2N), dedicated 2N redundant HV substations on-site"}, "provider": "NTT Global Networks", "providerId": 31, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/ntt-global-data-centers.png", "specifications": {"building": {"colocationSpace": 16145, "type": "NULL"}, "fireProtection": {"detection": "Fully addressable fire detection system with Very Early Smoke Detection Alarm (VESDA), interconnected to central BMS", "suppression": "Physical fire protection in hosting suites and all plant areas, gas suppression systems to technical areas"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "99.999% power uptime availability"}]
{"_geo": {"lat": 51.517402, "lng": -0.617943}, "amenities": ["Client Implementation Services", "Installation Services", "24/7 Remote Hands Services", "Facility Services", "Audit Support Services"], "certifications": ["ISO 9001", "ISO/IEC 27001", "ISO 22301", "ISO 50001", "ISO 45001", "ISO 14001", "PCI DSS", "ISAE 3402 Type 2 Report", "ISAE 3000 Type 2 Report"], "facility": {"address": "670 Ajax Avenue", "city": "Slough", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Carrier- and cloud-neutral", "Carrier-mix", "Connectivity and dark fiber infrastructure", "Carrier-Meet-Me-Rooms", "Redundant cabling infrastructure", "Pre-Cabling to support fast Cross Connect deployments", "High-performance internet access", "Inter data center connectivity between NTT data centers", "Multi Service Interconnection Platform"]}, "country": "United Kingdom", "name": "Slough 2", "overview": "Slough 2 Data Center is designed for flexible and evolving requirements. Located in the UK\u2019s second-largest data center cluster, it offers carrier-neutral connectivity, high-performance colocation, and robust security infrastructure. The facility provides tailored infrastructure with global connectivity options.", "state": "NULL", "stateAbbr": "NULL", "url": "/ntt-slough-2", "worldRegion": "europe", "yearBuilt": "NULL", "zipcode": "SL1 4BG"}, "hasSecurity": true, "id": 181, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Primary cooling infrastructure, centrally managed and linked to BMS, room air conditioning units, regulated humidity, 1.5m clear false ceiling void for hot-air return, contained hot aisle or chimney rack design", "redundancy": "NULL"}, "density": "1.8MW IT load", "standbyPower": {"configuration": "2N backup generators, refueling contracts to ensure timely replacement", "redundancy": "2N"}, "ups": {"configuration": "Minimum 2N UPS with battery backup", "redundancy": "2N"}, "utilityFeeders": "Dual dedicated 11,000V (HV) grid connections (2N), dedicated 2N redundant HV substations on-site"}, "provider": "NTT Global Networks", "providerId": 31, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/ntt-global-data-centers.png", "specifications": {"building": {"colocationSpace": 8611, "type": "NULL"}, "fireProtection": {"detection": "Fully addressable fire detection system with Very Early Smoke Detection Alarm (VESDA), interconnected to central BMS", "suppression": "Physical fire protection in hosting suites and all plant areas, gas suppression systems to technical areas"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "99.999% power uptime availability"}