[{"_geo": {"lat": 51.76491, "lng": -0.442532}, "amenities": ["Client Implementation Services", "Installation Services", "24/7 Remote Hands Services", "Facility Services", "Audit Support Services"], "certifications": ["ISO 9001", "ISO/IEC 27001", "ISO 22301", "ISO 50001", "ISO 45001", "ISO 14001", "PCI DSS", "ISAE 3402 Type 2 Report", "ISAE 3000 Type 2 Report"], "facility": {"address": "150 Maylands Avenue", "city": "Hemel Hempstead", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Carrier- and cloud-neutral", "Carrier-mix", "Connectivity and dark fiber infrastructure", "Carrier-Meet-Me-Rooms", "Redundant cabling infrastructure", "Pre-Cabling to support fast Cross Connect deployments", "High-performance internet access", "Inter data center connectivity between NTT data centers", "Multi Service Interconnection Platform"]}, "country": "United Kingdom", "name": "Hemel Hempstead 2", "overview": "Hemel Hempstead 2 Data Center is a fiber-connected campus that is fully integrated with NTT\u0027s other UK data centers, allowing clients to scale with ease. Strategically located with optimal proximity to Slough data centers and London 1 in Dagenham for backup, it offers a secure, high-performance colocation environment.", "state": "NULL", "stateAbbr": "NULL", "url": "/ntt-hemel-hempstead-2", "worldRegion": "europe", "yearBuilt": "NULL", "zipcode": "HP2 7DF"}, "hasSecurity": true, "id": 168, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Primary cooling infrastructure centrally managed and linked to BMS, room air conditioning units, regulated humidity, 1.5m clear false ceiling void for hot-air return to AHU, contained hot aisle or chimney rack design", "redundancy": "NULL"}, "density": "6.2MW maximum client IT load", "standbyPower": {"configuration": "2N backup generators, refueling contracts for timely replacement", "redundancy": "2N"}, "ups": {"configuration": "Minimum 2N UPS with battery backup", "redundancy": "2N"}, "utilityFeeders": "Dual dedicated 11,000V (HV) grid connections (2N), dedicated 2N redundant HV substations on-site"}, "provider": "NTT Global Networks", "providerId": 31, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/ntt-global-data-centers.png", "specifications": {"building": {"colocationSpace": 24756, "type": "NULL"}, "fireProtection": {"detection": "Very Early Smoke Detection Alarm system (VESDA), fire detection and suppression systems interconnected to central BMS", "suppression": "Physical fire protection in hosting suites and all plant areas, gas suppression systems to technical areas"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "99.999% power uptime availability"}, {"_geo": {"lat": 51.757802, "lng": -0.432844}, "amenities": ["Client Implementation Services", "Installation Services", "24/7 Remote Hands Services", "Facility Services", "Audit Support Services"], "certifications": ["ISO 9001", "ISO/IEC 27001", "ISO 22301", "ISO 50001", "ISO 45001", "ISO 14001", "PCI DSS", "ISAE 3402 Type 2 Report", "ISAE 3000 Type 2 Report"], "facility": {"address": "1 Blossom Way", "city": "Hemel Hempstead", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Carrier- and cloud-neutral", "Carrier-mix", "Connectivity and dark fiber infrastructure", "Carrier-Meet-Me-Rooms", "Redundant cabling infrastructure", "Pre-Cabling to support fast Cross Connect deployments", "High-performance internet access", "Inter data center connectivity between NTT data centers", "Multi Service Interconnection Platform"]}, "country": "United Kingdom", "name": "Hemel Hempstead 4", "overview": "Hemel Hempstead 4 Data Center is a high-availability colocation facility designed for growth and innovation. Part of NTT\u0027s UK data center portfolio, it provides carrier-neutral connectivity, robust security, and state-of-the-art infrastructure to support mission-critical IT workloads.", "state": "NULL", "stateAbbr": "NULL", "url": "/ntt-hemel-hempstead-4", "worldRegion": "europe", "yearBuilt": "NULL", "zipcode": "HP2 4ZB"}, "hasSecurity": true, "id": 170, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Primary cooling infrastructure, centrally managed and linked to BMS, contained hot aisle or chimney rack design, concurrently maintainable air handling units (AHUs), DX cooling to comms rooms (N+1 per room), direct air cooling to PODs (N+1 fans per section), DX cooling to POD battery rooms (N units per room), cold smoke extract system to data suites", "redundancy": "N+1"}, "density": "12MW IT load", "standbyPower": {"configuration": "Backup generators, refueling contracts to ensure timely replacement", "redundancy": "NULL"}, "ups": {"configuration": "Minimum N+1 UPS with battery backup", "redundancy": "N+1"}, "utilityFeeders": "Dual dedicated 11,000V (HV) grid connections (2N), dedicated N+1 redundant HV substations on-site"}, "provider": "NTT Global Networks", "providerId": 31, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/ntt-global-data-centers.png", "specifications": {"building": {"colocationSpace": 51666, "type": "NULL"}, "fireProtection": {"detection": "Very Early Smoke Detection Alarm system (VESDA), manual fire extinguishers throughout the facility", "suppression": "Physical fire protection in hosting suites and plant areas, gas suppression systems in technical areas, fire detection and suppression systems integrated into central BMS"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "99.999% power uptime availability"}]
{"_geo": {"lat": 51.7623, "lng": -0.43705}, "amenities": ["Client Implementation Services", "Installation Services", "24/7 Remote Hands Services", "Facility Services", "Audit Support Services"], "certifications": ["ISO 9001", "ISO/IEC 27001", "ISO 22301", "ISO 50001", "ISO 45001", "ISO 14001", "PCI DSS", "ISAE 3402 Type 2 Report", "ISAE 3000 Type 2 Report"], "facility": {"address": "Campus, Spring Way", "city": "Hemel Hempstead", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Carrier- and cloud-neutral", "Carrier-mix", "Connectivity and dark fiber infrastructure", "Carrier-Meet-Me-Rooms", "Redundant cabling infrastructure", "Pre-Cabling to support fast Cross Connect deployments", "High-performance internet access", "Inter data center connectivity between NTT data centers", "Multi Service Interconnection Platform"]}, "country": "United Kingdom", "name": "Hemel Hempstead 3", "overview": "Hemel Hempstead 3 Data Center is a high-availability colocation facility offering flexible deployments and carrier-neutral connectivity. It is part of NTT\u0027s UK data center portfolio, supporting seamless interconnection to major London data hubs and global infrastructure.", "state": "NULL", "stateAbbr": "NULL", "url": "/ntt-hemel-hempstead-3", "worldRegion": "europe", "yearBuilt": "NULL", "zipcode": "HP2 7TN"}, "hasSecurity": true, "id": 169, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Primary cooling infrastructure centrally managed and linked to BMS, room air conditioning units, regulated humidity, 1.5m clear false ceiling void for hot-air return, contained hot aisle or chimney rack design", "redundancy": "NULL"}, "density": "20MW IT load", "standbyPower": {"configuration": "N+1 backup generators, refueling contracts to ensure timely replacement", "redundancy": "N+1"}, "ups": {"configuration": "Minimum N+1 UPS with battery backup", "redundancy": "N+1"}, "utilityFeeders": "Dual dedicated 11,000V (HV) grid connections (2N), dedicated 2N redundant HV substations on-site"}, "provider": "NTT Global Networks", "providerId": 31, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/ntt-global-data-centers.png", "specifications": {"building": {"colocationSpace": 95798, "type": "NULL"}, "fireProtection": {"detection": "Very Early Smoke Detection Alarm system (VESDA), smoke detection early warning system, fire detection systems interconnected to BMS", "suppression": "Fire suppression systems in technical areas, physical fire protection in hosting suites and all plant areas"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "99.999% power uptime availability"}