General Information

Overview

Munich 2 Data Center is a highly secure, carrier-neutral facility in one of Europe’s leading ICT locations. The data center offers advanced cooling and power redundancy, high connectivity options, and sustainable energy management systems to support AI and cloud workloads.

Building Details

Network Providers

Carrier- and cloud-neutral

Carrier-Access-Rooms

Carrier-Meet-Me-Rooms

Carrier-mix

Connectivity and dark fiber infrastructure

Redundant cabling infrastructure

Pre-Cabling

High-performance internet access

Inter data center connectivity between NTT facilities

Multi Service Interconnection Platform

Amenities

No amenities listed

Media

No media available. See NTT Global Networks Media.

Contact

Complete the form to get in your information reviewed by

Get Started Today

Register Your Email Address with ColoCapacity

{}
{"_geo": {"lat": 48.2927217, "lng": 11.5739428}, "amenities": ["Client Implementation Services", "Installation Services", "Remote Hands Services", "Facility Services", "Additional Security Services"], "certifications": ["ISO 9001", "ISO 27001 IT-Grundschutz", "ISO 22301", "ISO 50001", "ISO 45001", "PCI DSS", "TISAX", "\u00a78a (3) BSIG/KRITIS", "EN 50600 (Building A \u0026 B)", "ISAE 3402 Type 2 Report", "ISAE 3000 Type 2 Report"], "facility": {"address": "Landshuter Stra\u00dfe 7", "city": "Unterschlei\u00dfheim", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Carrier- and cloud-neutral", "Carrier-Access-Rooms", "Carrier-Meet-Me-Rooms", "Carrier-mix", "Connectivity and dark fiber infrastructure", "Redundant cabling infrastructure", "Pre-Cabling", "High-performance internet access", "Inter data center connectivity between NTT facilities", "Multi Service Interconnection Platform"]}, "country": "Germany", "name": "Munich 2", "overview": "Munich 2 Data Center is a highly secure, carrier-neutral facility in one of Europe\u2019s leading ICT locations. The data center offers advanced cooling and power redundancy, high connectivity options, and sustainable energy management systems to support AI and cloud workloads.", "state": "NULL", "stateAbbr": "NULL", "url": "/ntt-munich-2", "worldRegion": "europe", "yearBuilt": "NULL", "zipcode": "85716"}, "hasSecurity": true, "id": 567, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "High-efficiency chiller systems with free cooling, additional groundwater cooling, CRAH units, concurrently maintainable air handling units (AHUs), cold aisle containment, heat recovery with heating pumps", "redundancy": "NULL"}, "density": "9.7MW IT load", "standbyPower": {"configuration": "Redundantly designed emergency power system with diesel generators (N+1 per building)", "redundancy": "N+1"}, "ups": {"configuration": "Two separate UPS systems (A- and B-supply) with 2N redundancy", "redundancy": "2N"}, "utilityFeeders": "Power supply at 20kV level"}, "provider": "NTT Global Networks", "providerId": 31, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/ntt-global-data-centers.png", "specifications": {"building": {"colocationSpace": 67812, "type": "NULL"}, "fireProtection": {"detection": "Very Early Smoke Detection Alarm system (VESDA), automatic digital fire alarm system", "suppression": "Firefighting system based on a nitrogen extinguishing gas system, fire protection walls with 90 minutes separation"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "99.999% power uptime availability"}