Data Center Map Colocation Bare Metal Facilities Regions Providers Quotes Contact

Similar Data Centers (22)

Washington DC15 Data Center, Ashburn, Virginia, United States

Culpeper CU3 Data Center, Culpeper, Virginia, United States

Ashburn VA5, Ashburn, Virginia, United States

Washington DC6 Data Center, Ashburn, Virginia, United States

Washington DC4 Data Center, Ashburn, Virginia, United States

Washington DC1 Data Center, Ashburn, Virginia, United States

Washington DC2 Data Center, Ashburn, Virginia, United States

Culpeper CU1 Data Center, Culpeper, Virginia, United States

Washington DC14 IBX Data Center, Manassas, Virginia, United States

Ashburn VA2, Ashburn, Virginia, United States

Washington DC13 Data Center, Ashburn, Virginia, United States

Washington DC12 IBX Data Center, Ashburn, Virginia, United States

Ashburn VA1, Ashburn, Virginia, United States

Ashburn VA3, Ashburn, Virginia, United States

Ashburn VA4, Ashburn, Virginia, United States

Culpeper CU2 Data Center, Culpeper, Virginia, United States

Washington DC3 Data Center, Ashburn, Virginia, United States

Washington DC5 Data Center, Ashburn, Virginia, United States

Washington DC7 Data Center, Vienna, Virginia, United States

Washington DC10 Data Center, Ashburn, Virginia, United States

Washington DC11 IBX Data Center, Ashburn, Virginia, United States

Washington DC21 Data Center, Ashburn, Virginia, United States

General Information

Overview

Equinix’s Culpeper CU4 data center is part of a highly secure and technologically advanced campus located 60 miles from Washington, D.C. The facility is designed for federal IT initiatives and government agencies, featuring multi-layered security, anti-ram fencing, and significant building setbacks for maximum protection.

Building Details

Network Providers

Equinix Internet Exchange

Metro Connect®

Cross Connects

Campus Cross Connect

Amenities

No amenities listed

Media

No media available. See Equinix Media.

Contact

Complete the form to get in your information reviewed by

Get Started Today

Register Your Email Address with ColoCapacity

[{"_geo": {"lat": 38.5119, "lng": -77.9926}, "amenities": ["Crash Carts", "Loaner Tools", "Wi-Fi", "Break Room (Admin Building CU6)", "Conference Room(s) (Admin Building CU6)", "Showers (Admin Building CU6)", "Work Kiosks (Admin Building CU6)", "Private Cage", "Secure Cabinet", "AC Power Circuits", "DC Power Circuits", "Antenna", "Equinix Fabric\u00ae", "Equinix Internet Access", "Equinix Internet Exchange\u00ae", "Metro Connect\u00ae", "Campus Cross Connect", "Cross Connects", "Equinix Precision Time\u00ae", "Smart Hands\u00ae", "Equinix Smart Build", "Equinix Smart View"], "certifications": ["HECVAT", "HIPAA", "ISO 22301", "ISO 27001", "NIST 800-53/FISMA High", "PCI DSS", "SOC 1 Type II", "SOC 2 Type II"], "facility": {"address": "18155 Technology Drive, Building C", "city": "Culpeper", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Equinix Internet Exchange", "Metro Connect\u00ae", "Cross Connects", "Campus Cross Connect"]}, "country": "United States", "name": "Culpeper CU3 Data Center", "overview": "Equinix\u2019s Culpeper CU3 data center is part of a highly secure and technologically advanced campus located 60 miles from Washington, D.C. The facility is designed for federal IT initiatives and government agencies, featuring multi-layered security, anti-ram fencing, and significant building setbacks for maximum protection.", "state": "Virginia", "stateAbbr": "VA", "url": "/equinix-culpeper-cu3-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "22701"}, "hasSecurity": true, "id": 254, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Air-cooled chillers, CRAHs", "redundancy": "N+1"}, "density": "3.0 kVA per cabinet", "standbyPower": {"configuration": "4 x 2,500 kW diesel generators, 2 x 1,500 kW diesel generators", "redundancy": "N+1"}, "ups": {"configuration": "Distributed redundant", "redundancy": "N+1"}, "utilityFeeders": 2}, "provider": "Equinix", "providerId": 16, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/equinix.png", "specifications": {"building": {"colocationSpace": 39535, "type": "1-story, steel-framed building with precast concrete panel"}, "fireProtection": {"detection": "Air sampling smoke detection, VESDA, water leak, fuel leak", "suppression": "Non-aspirated (duct/ceiling-mount), double-interlocked pre-action (dry pipe)"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "\u003e99.9999% globally"}, {"_geo": {"lat": 38.5117, "lng": -77.9928}, "amenities": ["Crash Carts", "Loaner Tools", "Wi-Fi", "Break Room (Admin Building CU6)", "Conference Room(s) (Admin Building CU6)", "Showers (Admin Building CU6)", "Work Kiosks (Admin Building CU6)", "Private Cage", "Secure Cabinet", "AC Power Circuits", "DC Power Circuits", "Antenna", "Equinix Fabric\u00ae", "Equinix Internet Access", "Equinix Internet Exchange\u00ae", "Metro Connect\u00ae", "Campus Cross Connect", "Cross Connects", "Equinix Precision Time\u00ae", "Smart Hands\u00ae", "Equinix Smart Build", "Equinix Smart View"], "certifications": ["HECVAT", "HIPAA", "ISO 22301", "ISO 27001", "NIST 800-53/FISMA High", "PCI DSS", "SOC 1 Type II", "SOC 2 Type II"], "facility": {"address": "18155 Technology Drive, Building A", "city": "Culpeper", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Equinix Internet Exchange", "Metro Connect\u00ae", "Cross Connects", "Campus Cross Connect"]}, "country": "United States", "name": "Culpeper CU1 Data Center", "overview": "Equinix\u2019s Culpeper CU1 data center is part of a highly secure and technologically sophisticated campus located 60 miles from Washington, D.C. The facility is designed to support federal IT initiatives and government agencies, featuring multi-layered armed security, anti-ram fencing, and 150-ft. building setbacks for maximum protection.", "state": "Virginia", "stateAbbr": "VA", "url": "/equinix-culpeper-cu1-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "22701"}, "hasSecurity": true, "id": 775, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Air-cooled chillers, CRAHs", "redundancy": "N+1"}, "density": "4.0 kVA per cabinet", "standbyPower": {"configuration": "6 x 2,250 kW diesel generators", "redundancy": "N+2"}, "ups": {"configuration": "Distributed redundant", "redundancy": "N+1"}, "utilityFeeders": 2}, "provider": "Equinix", "providerId": 16, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/equinix.png", "specifications": {"building": {"colocationSpace": 45273, "type": "1-story, steel-framed building with precast concrete panel"}, "fireProtection": {"detection": "NULL", "suppression": "Non-aspirated (duct/ceiling-mount)/double-interlocked pre-action (dry pipe)"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "\u003e99.9999% globally"}, {"_geo": {"lat": 38.5118, "lng": -77.9927}, "amenities": ["Crash Carts", "Loaner Tools", "Wi-Fi", "Break Room (Admin Building CU6)", "Conference Room(s) (Admin Building CU6)", "Showers (Admin Building CU6)", "Work Kiosks (Admin Building CU6)", "Private Cage", "Secure Cabinet", "AC Power Circuits", "DC Power Circuits", "Antenna", "Equinix Fabric\u00ae", "Equinix Internet Access", "Equinix Internet Exchange\u00ae", "Metro Connect\u00ae", "Campus Cross Connect", "Cross Connects", "Equinix Precision Time\u00ae", "Smart Hands\u00ae", "Equinix Smart Build", "Equinix Smart View"], "certifications": ["HECVAT", "HIPAA", "ISO 22301", "ISO 27001", "NIST 800-53/FISMA High", "PCI DSS", "SOC 1 Type II", "SOC 2 Type II"], "facility": {"address": "18155 Technology Drive, Building B", "city": "Culpeper", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Equinix Internet Exchange", "Metro Connect\u00ae", "Cross Connects", "Campus Cross Connect"]}, "country": "United States", "name": "Culpeper CU2 Data Center", "overview": "Equinix\u2019s Culpeper CU2 data center is part of a highly secure and technologically advanced campus located 60 miles from Washington, D.C. The facility is designed for federal IT initiatives and government agencies, featuring multi-layered security, anti-ram fencing, and significant building setbacks for maximum protection.", "state": "Virginia", "stateAbbr": "VA", "url": "/equinix-culpeper-cu2-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "22701"}, "hasSecurity": true, "id": 1249, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Air-cooled chillers, CRAHs", "redundancy": "N+1"}, "density": "4.0 kVA per cabinet", "standbyPower": {"configuration": "6 x 2,250 kW diesel generators, 2 x 1,500 kW diesel generators", "redundancy": "N+1"}, "ups": {"configuration": "Distributed redundant", "redundancy": "N+1"}, "utilityFeeders": 2}, "provider": "Equinix", "providerId": 16, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/equinix.png", "specifications": {"building": {"colocationSpace": 62398, "type": "1-story, steel-framed building with precast concrete panel"}, "fireProtection": {"detection": "NULL", "suppression": "Non-aspirated (duct/ceiling-mount), double-interlocked pre-action (dry pipe)"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "\u003e99.9999% globally"}]
{"_geo": {"lat": 38.512, "lng": -77.9925}, "amenities": ["Crash Carts", "Loaner Tools", "Wi-Fi", "Break Room (Admin Building CU6)", "Conference Room(s) (Admin Building CU6)", "Showers (Admin Building CU6)", "Work Kiosks (Admin Building CU6)", "Private Cage", "Secure Cabinet", "AC Power Circuits", "DC Power Circuits", "Antenna", "Equinix Fabric\u00ae", "Equinix Internet Access", "Equinix Internet Exchange\u00ae", "Metro Connect\u00ae", "Campus Cross Connect", "Cross Connects", "Equinix Precision Time\u00ae", "Smart Hands\u00ae", "Equinix Smart Build", "Equinix Smart View"], "certifications": ["HECVAT", "HIPAA", "ISO 22301", "ISO 27001", "NIST 800-53/FISMA High", "PCI DSS", "SOC 1 Type II", "SOC 2 Type II"], "facility": {"address": "18155 Technology Drive, Building D", "city": "Culpeper", "connectivity": {"hasHyperscale": false, "hasInterconnect": true, "hasRetail": false, "hasWholesale": false, "networkProviders": ["Equinix Internet Exchange", "Metro Connect\u00ae", "Cross Connects", "Campus Cross Connect"]}, "country": "United States", "name": "Culpeper CU4 Data Center", "overview": "Equinix\u2019s Culpeper CU4 data center is part of a highly secure and technologically advanced campus located 60 miles from Washington, D.C. The facility is designed for federal IT initiatives and government agencies, featuring multi-layered security, anti-ram fencing, and significant building setbacks for maximum protection.", "state": "Virginia", "stateAbbr": "VA", "url": "/equinix-culpeper-cu4-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "22701"}, "hasSecurity": true, "id": 270, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Air-cooled chillers, CRAHs", "redundancy": "N+1"}, "density": "4.0 kVA per cabinet", "standbyPower": {"configuration": "4 x 2,500 kW diesel generators", "redundancy": "N+1"}, "ups": {"configuration": "Block redundant", "redundancy": "N+1"}, "utilityFeeders": 2}, "provider": "Equinix", "providerId": 16, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/equinix.png", "specifications": {"building": {"colocationSpace": 52667, "type": "1-story, steel-framed building with precast concrete panel"}, "fireProtection": {"detection": "NULL", "suppression": "Non-aspirated (duct/ceiling-mount), double-interlocked pre-action (dry pipe)"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "\u003e99.9999% globally"}