Colocation Bare Metal Data Center Map Providers Marketplace Quotes Contact

General Information

Overview

NVA5 facility will be a two story building and at full build will offer over 1 million square feet of data center space. It will provide up to 90,000 square feet of class A office space. The location offers direct access to one of the largest internet exchange points in the US and superior fiber connectivity.

Certifications

No certifications available. See Provider Certifications.

Building Details

Network Providers

CyrusOne Internet Exchange (IX)

Amenities

No amenities listed

Media

No media available. See CyrusOne Media.

Contact

Complete the form to get in your information reviewed by

Get Started Today

Register Your Email Address with ColoCapacity

[{"_geo": {"lat": 39.0417, "lng": -77.4227}, "amenities": ["24\u00d77 staffed NOCC and remote hands support", "Dedicated cages and private suite options available", "State-of-the-art offices, fitness center, staging room and hoteling space", "24/7 year-round onsite data center security guards", "Video surveillance and recording of exteriors and interiors", "Biometric and key card security for strict access control", "Turn style and other secure doors to prevent tail gating", "Reinforced physical infrastructure that can include concrete bollards, steel-lined walls, and bullet resistant glass", "Dedicated data halls, suites and cages to minimize traffic", "6,800-gallon belly tanks for each generator (supports critical load for 48-hours) with diverse refueling agreements"], "certifications": ["ISO/IEC 27001", "PCI DSS", "HIPAA/HITECH", "FISMA-High", "HITRUST", "FFIEC", "CSA STAR", "TRUSTe", "SSAE 18 (SOC 1 Type II)", "Type 2 AT 101/SOC 2", "Business Continuity and Disaster Recovery (BCDR)"], "facility": {"address": "21111 Ridgetop Circle", "city": "Sterling", "connectivity": {"hasHyperscale": true, "hasInterconnect": true, "hasRetail": true, "hasWholesale": true, "networkProviders": ["CyrusOne Internet Exchange (IX)"]}, "country": "United States", "name": "Northern Virginia NVA Data Center", "overview": "This NVA1, NVA2 and NVA3 data centers are an enterprise-class facility located in Sterling, Virginia. The data center campus is 420,000 square feet and sits on 14 acres. With direct access to one of the largest Internet Exchange points in the U.S., superior fiber connectivity makes this data center ideal for colocation of high performance computing, for which CyrusOne is known. It\u0027s conveniently located near dozens of hotels, restaurants and other amenities and only eight miles from Dulles International Airport and 30 minutes from Ronald Reagan Washington Airport.", "state": "Virginia", "stateAbbr": "VA", "url": "/cyrusone-northern-virginia-sterling-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "20166"}, "hasSecurity": true, "id": 1060, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "36-inch raised floor design, Utilizing Stulz 200-ton CRAH units with electronically commutated (EC) variable-speed fans, Highly-efficient 500-ton Trane chillers with rapid restart and adaptive controlled microprocessors", "redundancy": "Ability to scale as density increases in an N+1 central plant design and an N+2 air-side design"}, "density": "High Performance Computing (HPC) capable, supports 200 watts/sf with the ability to support over 1,000 watts/sf", "standbyPower": {"configuration": "85.5MW dedicated diesel generators", "redundancy": "N+1"}, "ups": {"configuration": "Multiple levels of redundancy available within the same footprint (i.e. N, Distributed Redundant, 2N, or a combination), Dual-Input PDUs with Static Transfer Switches (STS\u0027s)", "redundancy": "N+1"}, "utilityFeeders": "48 MW of critical power at N and 36 MW at distributed redundant"}, "provider": "CyrusOne", "providerId": 7, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/cyrusone.avif", "specifications": {"building": {"colocationSpace": 420000, "type": "NULL"}, "fireProtection": {"detection": "NULL", "suppression": "Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled with a zonal dual-action interlocking dry-pipe pre-action system"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "This location is in an area considered one of the safest in the country: free from natural disasters including seismic activity, tornados and hurricanes"}}, "uptime": "100% Uptime service level agreement on power"}, {"_geo": {"lat": 39.0445, "lng": -77.4285}, "amenities": ["CCTV Camera System 24\u00d77", "Biometric \u0026 Photo Badge Access", "Video surveillance and recording of the exterior and interior", "On-site security guards 24/7 year-round", "Dual authentication entry into building and data halls; biometric and key card (color-coded) security for rigid access control", "Cabinet and cage security options include individual locks and biometric scanners", "Perimeter fence", "6,800-gallon belly tank per generator", "Closed-loop chilled-water-cooling design"], "certifications": ["NULL"], "facility": {"address": "22811 International Drive", "city": "Sterling", "connectivity": {"hasHyperscale": true, "hasInterconnect": true, "hasRetail": true, "hasWholesale": true, "networkProviders": ["Excellent Fiber Connectivity"]}, "country": "United States", "name": "Northern Virginia NVA4 Data Center", "overview": "Located at 22811 International Drive, CyrusOne\u0027s 130,000 square feet data center built on a 10 acre lot. Designed to CyrusOne\u0027s power, cooling, and security standards, the facility offers up to 12.6 Megawatts (MW) of power. The facility is about 5 miles away from Dulles International airport and 4 miles from CyrusOne Sterling facility.", "state": "Virginia", "stateAbbr": "VA", "url": "/cyrusone-northern-virginia-sterling-nva4-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "20116"}, "hasSecurity": true, "id": 1061, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "36-inch raised white floor design, 24 foot ceiling height from data center floor, utilizing Stultz 200 Ton CRAH\u0027s units with electronically commutated (EC) variable-speed fans, Highly efficient multiple 500-ton Trane chillers with rapid restart and adaptive controlled microprocessors", "redundancy": "N+1"}, "density": "Up to 1000 W per square foot", "standbyPower": {"configuration": "Scalable 2.25MW Detroit Diesel dedicated generators pre-wired for additional capacity", "redundancy": "N+1"}, "ups": {"configuration": "750kVA Mitsubishi UPS systems; each power leg has a dedicated UPS with battery backup", "redundancy": "Multiple levels of redundancy available within the same footprint (e.g., N, 2N)"}, "utilityFeeders": "Diverse power delivered by two independent circuits"}, "provider": "CyrusOne", "providerId": 7, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/cyrusone.avif", "specifications": {"building": {"colocationSpace": 128715, "type": "NULL"}, "fireProtection": {"detection": "NULL", "suppression": "Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled with a zonal dual-action interlocking dry-pipe pre-action system"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "Seismic Zone 1"}}, "uptime": "NULL"}, {"_geo": {"lat": 39.0448, "lng": -77.4112}, "amenities": ["Physical \u2013 Anti-Scale fence around the property, electronic gates and gate arms at entrance to the site", "Guards \u2013 Secure entry into space via Security Office with guards", "Electronic \u2013 Electronic surveillance, card reader access control to building and space", "Perimeter fence", "Closed-loop chilled water system", "7,362 square feet of office/storage space", "Various restaurants and hotels nearby", "Dulles International Airport \u2013 8 miles", "Washington National Airport \u2013 35 miles"], "certifications": ["NULL"], "facility": {"address": "21350 Pacific Blvd.", "city": "Sterling", "connectivity": {"hasHyperscale": true, "hasInterconnect": true, "hasRetail": true, "hasWholesale": true, "networkProviders": ["CyrusOne Internet Exchange (IX)"]}, "country": "United States", "name": "Northern Virginia NVA7 Data Center", "overview": "Located at 21350 Pacific Blvd, Sterling, VA, CyrusOne\u0027s NVA7 data center provides 177,019 square feet of total space with 89,097 square feet of raised access floor for data hall operations.", "state": "Virginia", "stateAbbr": "VA", "url": "/cyrusone-northern-virginia-sterling-nva7-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "20166"}, "hasSecurity": true, "id": 1063, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Chiller Plant \u2013 Each hall is nominally 6 MW at N+1. Data Hall \u2013 225-ton CRAH units", "redundancy": "N+2 configuration"}, "density": "NULL", "standbyPower": {"configuration": "Generator Power \u2013 33.75MW plus 1.75MW house", "redundancy": "N+1"}, "ups": {"configuration": "UPS Configuration and capacity \u2013 6MW block redundant, 5-make-4 blocks", "redundancy": "N+1"}, "utilityFeeders": "Utility Capacity \u2013 Approximately 150-175MW, with 30MW available for S7 plus a little bit of load over in S5. Utility Voltage \u2013 34.5kV. Number of Utility Feeders \u2013 Two currently with the third on the way, end game is five including the service to permanently feed S7."}, "provider": "CyrusOne", "providerId": 7, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/cyrusone.avif", "specifications": {"building": {"colocationSpace": 89097, "type": "Precast concrete panels with slab on grade"}, "fireProtection": {"detection": "Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled with a zonal dual-action interlocking dry-pipe pre-action system", "suppression": "Double interlock pre-action sprinklers in all critical areas and circulation corridors. Wet sprinklers in office area"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "NULL"}, {"_geo": {"lat": 39.0402, "lng": -77.4017}, "amenities": ["24MW critical IT capacity", "CCTV Camera System 24\u00d77", "Biometric \u0026 Photo Badge Access", "Physical \u2013 Anti-Scale fence, electronic gates and gate arms", "Guards \u2013 Secure entry into space via Security Office with guards", "Electronic \u2013 Electronic surveillance, card reader access control to building and space", "Ultra Low PUE through the use of a closed loop chilled water system", "Distance from the airports \u2013 7.0 Miles", "Distance to other C1 sites in Metro area (if any) \u2013 0.5 Miles", "Amenities \u2013 Hilton, Hyatt, Marriott, Homewood Suites, Holiday Inn, Embassy Suites", "Restaurants \u2013 High number of restaurants in Sterling and Ashburn", "Data hall white floor space is 1,500lbs p/SF", "CRAH gallery floor capacity is 2,500lbs p/SF"], "certifications": ["ISO/IEC 27001", "PCI DSS", "HIPAA/HITECH", "FISMA-High", "HITRUST", "FFIEC", "CSA STAR", "TRUSTe", "SSAE 18 (SOC 1 Type II)", "Type 2 AT 101/SOC 2", "Business Continuity and Disaster Recovery (BCDR)"], "facility": {"address": "45905 Maries Road", "city": "Sterling", "connectivity": {"hasHyperscale": true, "hasInterconnect": true, "hasRetail": true, "hasWholesale": true, "networkProviders": ["Carrier-neutral and part of the CyrusOne Internet Exchange (IX)", "Excellent Fiber Connectivity"]}, "country": "United States", "name": "Northern Virginia NVA8 Data Center", "overview": "Located at 45905 Maries Road, CyrusOne\u0027s NVA8 is a 154,230 square feet data center built with 100,341 square feet of raised white floor, 5,210 square feet of office space and has 15,327 square feet of support. The facility is about 7 miles away from airports and 0.5 miles from CyrusOne Sterling facility.", "state": "Virginia", "stateAbbr": "VA", "url": "/cyrusone-northern-virginia-sterling-nva8-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "20166"}, "hasSecurity": true, "id": 1064, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "Plant \u2013 10,000-ton air cooled chiller plant, Data Hall \u2013 225-ton CRAH units", "redundancy": "N+2 configuration"}, "density": "NULL", "standbyPower": {"configuration": "Generator power \u2013 45MW plus 1.5MW house", "redundancy": "N+1"}, "ups": {"configuration": "UPS configuration and capacity \u2013 4MW block redundant, mix of 4-make-3 and 6-make-5 blocks", "redundancy": "N+1"}, "utilityFeeders": "Utility capacity \u2013 24MW critical IT capacity, Utility voltage \u2013 34.5kV, # of Utility Feeders \u2013 one currently planned, possibly two long term (for capacity, not redundancy)"}, "provider": "CyrusOne", "providerId": 7, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/cyrusone.avif", "specifications": {"building": {"colocationSpace": 100341, "type": "Construction Type \u2013 Precast Concrete Panels with slab on grade. Steel reinforced overhead structure with modified built-up roofing membrane to meet specific wind up-lift parameters."}, "fireProtection": {"detection": "Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled with a zonal dual-action interlocking dry-pipe pre-action system", "suppression": "Double interlock pre-action sprinklers in all critical areas and circulation corridors. Wet sprinklers in office area"}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "NULL"}, {"_geo": {"lat": 39.0232, "lng": -77.4416}, "amenities": ["700,000 total square feet", "400,000 square feet of raised white floor", "50,000 square feet of office space", "30,000 square feet of support space", "53,000 square feet of common areas and hallways", "Security Fencing, Entrance Gates", "Full Time guards on Site", "Ultra Low PUE through the use of a closed loop chilled water system", "Physical \u2013 8\u0027 high perimeter steel ornamental exterior fencing", "Anti-tailgating system with raising and lowering arms at vehicle entrance", "Electronic \u2013 A security system with card readers, badge readers, bio-readers", "Access parameters are controlled through local onsite guards", "1st floor DH \u2013 250 psf dead load, 2000 lbs concentrated load", "2nd Floor DH \u2013 250 psf dead load, 100 psf hanging load below floor"], "certifications": ["ISO/IEC 27001", "PCI DSS", "HIPAA/HITECH", "FISMA-High", "SSAE 18 (SOC 1 Type II)", "Type 2 AT 101/SOC 2", "Business Continuity and Disaster Recovery (BCDR)"], "facility": {"address": "43290 Old Ox Road", "city": "Sterling", "connectivity": {"hasHyperscale": true, "hasInterconnect": true, "hasRetail": true, "hasWholesale": true, "networkProviders": ["Carrier Neutral and part of the CyrusOne IX Exchange"]}, "country": "United States", "name": "Northern Virginia NVA9 Data Center", "overview": "Located at 43290 Old Ox Road in Sterling, Virginia, CyrusOne\u0027s NVA9 data center offers 700,000 total square feet with 400,000 square feet of raised white floor space. The facility includes 50,000 square feet of office space and 30,000 square feet of support areas.", "state": "Virginia", "stateAbbr": "VA", "url": "/cyrusone-northern-virginia-sterling-nva9-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "20166"}, "hasSecurity": true, "id": 1065, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "York Roof Mounted Air Cooled Chillers, 530 tons x 70 each = 37,100 total tons of DH cooling", "redundancy": "N+1"}, "density": "NULL", "standbyPower": {"configuration": "Generator power \u2013 2250 kw x 80 each = 180 MW", "redundancy": "N+1"}, "ups": {"configuration": "UPS configuration and capacity \u2013 4:3 distributed redundant, 1500 kw each", "redundancy": "N+1"}, "utilityFeeders": "Utility capacity \u2013 135 MW total, Utility voltage \u2013 34.5 KV, # of Utility Feeders \u2013 5 primary (5 redundant)"}, "provider": "CyrusOne", "providerId": 7, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/cyrusone.avif", "specifications": {"building": {"colocationSpace": 400000, "type": "Construction type \u2013 II-B, Building type \u2013 Data Center (Precast Structure/Fa\u00e7ade)"}, "fireProtection": {"detection": "Fire detection \u2013 VESDA for DH.", "suppression": "Fire suppression \u2013 Pre-Action, NFPA 13 Compliant for DH. Wet system for Offices."}, "floodAndSeismic": {"floodZone": "NULL", "seismicRating": "NULL"}}, "uptime": "NULL"}]
{"_geo": {"lat": 39.0447, "lng": -77.4113}, "amenities": ["24/7 year-round staffed NOCC and remote hands support", "Dedicated cages and private suite options available", "Wholesale and retail colocation options", "Water Free Cooling: No water is used to cool this facility (such as water towers or evaporative cooling). Minimal amounts of water are used for humidification and facility maintenance.", "Video surveillance and recording of the exterior and interior", "On-site security guards 24/7 year-round", "Dual authentication entry into building and data halls; biometric and key card (color-coded) security for rigid access control", "Cabinet and cage security options include individual locks and biometric scanners", "Perimeter fence", "6,800-gallon belly tank per generator", "Closed-loop chilled-water-cooling design"], "certifications": ["NULL"], "facility": {"address": "21350 Pacific Blvd.", "city": "Sterling", "connectivity": {"hasHyperscale": true, "hasInterconnect": true, "hasRetail": true, "hasWholesale": true, "networkProviders": ["CyrusOne Internet Exchange (IX)"]}, "country": "United States", "name": "Northern Virginia NVA5 Data Center", "overview": "NVA5 facility will be a two story building and at full build will offer over 1 million square feet of data center space. It will provide up to 90,000 square feet of class A office space. The location offers direct access to one of the largest internet exchange points in the US and superior fiber connectivity.", "state": "Virginia", "stateAbbr": "VA", "url": "/cyrusone-northern-virginia-sterling-nva5-data-center", "worldRegion": "northamerica", "yearBuilt": "NULL", "zipcode": "20166"}, "hasSecurity": true, "id": 1062, "media": ["NULL"], "powerAndCooling": {"cooling": {"configuration": "36-inch raised white floor design, 24 foot ceiling height from data center floor, utilizing Stultz 200 Ton CRAH\u0027s units with electronically commutated (EC) variable-speed fans, Highly efficient multiple 500-ton Trane chillers with rapid restart and adaptive controlled microprocessors", "redundancy": "N+1"}, "density": "Up to 1000 W per square foot", "standbyPower": {"configuration": "Scalable 2.25MW Detroit Diesel dedicated generators pre-wired for additional capacity", "redundancy": "N+1"}, "ups": {"configuration": "750kVA Mitsubishi UPS systems; each power leg has a dedicated UPS with battery backup", "redundancy": "Multiple levels of redundancy available within the same footprint (e.g., N, 2N)"}, "utilityFeeders": "Diverse power delivered by two independent circuits"}, "provider": "CyrusOne", "providerId": 7, "providerLogo": "https://colo.nyc3.cdn.digitaloceanspaces.com/logos/cyrusone.avif", "specifications": {"building": {"colocationSpace": 1000000, "type": "NULL"}, "fireProtection": {"detection": "NULL", "suppression": "Very Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million coupled with a zonal dual-action interlocking dry-pipe pre-action system"}, "floodAndSeismic": {"floodZone": "Zone X flood zone rating (low risk)", "seismicRating": "Zone 1 seismic zone rating (low risk)"}}, "uptime": "100% uptime service level agreement"}